Product Details:
Weight | 200 gms |
Dimension | (mm) 175 (L) x70 (W) x 33 (H) |
pH Range | 2 - 12 |
pH Accuracy | +/-0.1 |
pH Resolution | 0.01 |
Salinity Range | 0 to 42 ppt |
Salinity Accuracy | +/- 1 |
Salinity Resolution | 0.1 ppt |
Product Details:
Brand | Eutech |
Model No | DO-700 |
Power Requirements | 9 V DC adapter, 1.3 A (100/240 VAC, SMPS) |
Temperature Range | 0.0 to 100.0 deg C / 32.0 to 212.0 deg F |
pH Resolution | 0.01 pH |
pH Accuracy | +-0.01 pH |
Ion Concentration | 0.01 to 2000 ppm (+-2000 mV) |
Compensation | ATC / MTC (0 to 100 deg C) (pH only) |
Applications:
Product Details:
Brand | Hanna |
Model | HI-9147 |
Weight | 450 g (15.9 oz.) |
Battery Type | 1.5V AAA (3) |
Battery Life | 1,000 hours approx |
Dimensions | 185 x 72 x 36 mm (7.3 x 2.8 x 1.4") |
Environment | 0 to 50 deg C (32 to 122 deg F); RH max 95% non-condensing |
Salinity Compensation | 0 to 51 g/L (ppt) (1 g/L resolution) |
The HI-9147 is designed for aquaculture applications. This unit is unique among the Hanna family of DO meters as it is supplied with a galvanic probe.
Unlike Polarographic probes, galvanic DO probes require no conditioning time. When you need to measure multiple samples in a given period of time, pick it up and measure on demand.
The HI-9147 is a must have for DO sensitive organisms or high bio-load environments.
Product Details:
Brand | Lutron |
Display | 13 mm (0.5") |
Weight | 998 g |
Temperature | 0 to 50 C |
Dissolved Oxygen | 0 to 20.0 mg/L |
Oxygen in Air | 0 to 100.0%0 |
Dimensions | 25 x 13 x 6 cm |
Model No | DO-5510 |
Product Details:
Power Supply | DC 1.5V |
Weight | 176 g/0.39 LB. |
Battery Type | (UM-4/AAA ) x 4 PCs |
Dimension | 180 x 40 x 40 mm (7.1 x 1.6 x 1.6 inch) |
Power Current | Approx. DC 6.2 mA |
Operating Humidity | Less than 80% RH |
Operating Temperature | 0 to 50 deg C |
Display LCD Size | 29 mm x 28 mm. Dual function LCD |
Product Details:
Brand | Hanna |
Model | HI-9142 |
Resolution | 0.1 mg/L (ppm) |
Range | 0.0 to 19.9 mg/L (ppm) |
Weight | 300 g (10.6 oz.) |
Temperature | -5.0 to 50.0 deg C (32.0 to 122.0 deg F) |
Battery Type | 1.5V AAA (3) |
Battery Life | Approximately 1,000 hours of continuous use |
Product Details:
Minimum Order Quantity | 1 Piece |
Application | Industrial |
Brand | YSI |
Model Number/Name | Ecosense DO 200 |
Automation Grade | Automatic |
I deal in | New Only |
The EcoSense® line of compact, handheld instruments provides the most accurate data in the most affordable format. The instruments feature an easy-to-use interface, one-hand operation, IP67 waterproof case, and low cost of ownership over the life of the product. The DO200A simultaneously measures dissolved oxygen (% air saturation and ppm) and temperature with the following features:
• IP67 Waterproof housing
• Automatic temperature compensation
• 1-year instrument warranty
• 4- and 10-meter field cables available or lab self-stirring BOD probe
• Manual input for salinity and pressure compensation
• Low battery indicator with 500 hour battery life
• Screw-on cap membranes with low stirring and fast response
• Auto shutoff function after 30 minutes of inactivity
• 50 data set memory
DO200A System Specifications (Instrument, Probe, and Cable) | ||
Temperature °C, °F | Range | 23 to 131°F (-5 to 55°C) 0 to 45°C for DO compensation for mg/L |
Resolution | 0.1°F (0.1°C) | |
Accuracy | ±0.6°F (±0.3°C) | |
Dissolved Oxygen % Saturation % Local | Range | 0 to 500% |
Resolution | 0.1% or 1% air saturation (user selectable) | |
Accuracy | 0 to 200% air saturation, ±2% of the reading or ±2% air saturation, whichever is greater; 200 to 500% air saturation, ±6% of the reading | |
Dissolved Oxygen mg/L ppm | Range | 0 to 50 mg/L |
Resolution | 0.01 or 0.1 mg/L (user selectable) | |
Accuracy | 0 to 20 mg/L, ±2% of the reading or ±0.2 mg/L, whichever is greater; 20 to 50 mg/L, ±6% of the reading | |
Barometer mmHg, mbar, inHg psi, kPa | Range | 400 to 999.9 mmHg |
Resolution | 0.1 mmHg | |
Accuracy | ±5 mmHg within ±5°C temperature range from calibration point |
Product Details:
Minimum Order Quantity | 1 Piece |
Application | Industrial |
Brand | YSI |
Model Number/Name | ODO 200 |
Automation Grade | Automatic |
I deal in | New Only |
The EcoSense® line of compact, handheld instruments provides the most accurate data in the most affordable format. The instruments feature an optical dissolved oxygen sensor, easy-to-use interface, low maintenance requirements, accurate and repeatable measurements, and low cost of ownership over the life of the product. The ODO200 simultaneously measures dissolved oxygen and temperature with the following features.
• Optical sensors mean worry free accurate measurements, holds cal for several months, no stirring required, no electrodes to clean or membranes to change and no effect from gases such as H2S
• Automatic temperature compensation; Manual input for salinity and pressure compensation
• Weighted, 1-, 4- and 10-meter durable field probes/cables; detachable
• Low battery indicator with 100 hour battery life
• Replaceable optical sensor cap with 1-year warranty (12-18 month life)
• Auto shutoff function after 30 minutes of inactivity
• 50 data set reviewable memory
• 1-year instrument, cable and sensor cap warranty
The ODO200 is designed for quick, accurate results in an economical platform. The ability to measure DO optically along with temperature, in a simple, compact handheld allows the instrument to be used across multiple application sampling strategies in the field. With a one-year instrument, probe and sensor cap warranty, IP67 waterproof case and ease-of-use, the EcoSense ODO200 will fit your needs.
ODO 200 System Specifications (Instrument, Probe, and Cable) | ||
Temperature °C, °F | Range | 0 to 50°C (32 to 122°F) |
Resolution | 0.1°C | |
Accuracy | ±0.3°C | |
Dissolved Oxygen % Saturation % Local | Range | 0 to 200% |
Resolution | 1 or 0.1% | |
Accuracy | ±1.5% of reading or ±1.5%; whichever is greater | |
Dissolved Oxygen mg/L ppm | Range | 0 to 20 mg/L |
Resolution | 0.01 mg/L | |
Accuracy | ±1.5% of reading or ±0.15 mg/L; whichever is greater | |
Barometer, mbar,
| Range | 500 to 1125 mBar (manual input during calibration) |
Resolution | 1 mBar | |
Accuracy | ±5 mmHg within ±5°C temperature range from calibration point | |
Salinity (ppt) | Range | 0 to 40 ppt (manual input during calibration) |
Product Details:
Minimum Order Quantity | 1 pc |
Application | Industrial |
Automation Grade | Automatic |
Easy to use, rugged and reliable, the YSI Pro20i provides
everything you need in a handheld instrument for the
measurement of dissolved oxygen (DO). A true field instrument
with IP-67 waterproof, rubber over molded case, military spec
connectors and 1-meter drop tests ensure durability to provide
years of sampling even in the harshest field conditions.
With the Pro20i, accuracy is not compromised for ruggedness.
The Pro20i can easily be calibrated for fast, accurate
measurements you can trust.
• Integral (i.e. built-in) cable with 1- 4- 10-m field cable
• User-replaceable DO sensors
• One Touch Cal allows for easy DO calibrations within 3 seconds
with the press of a button
• Automatic barometric pressure compensation
• Quick response times; T-95 response time in 8 seconds with
standard membrane (fastest response time on the market)
• Stores 50 data sets; no need to write down data
• Large graphic, backlit display and glow in the dark keypad,
visible in any lighting condition
• Display is visible when wearing polarized sunglasses
• A true field instrument with IP-67, impact-resistant, waterproof
case. Waterproof with and without the battery cover.
• Rubber over molded, slip-proof case provides extra durability
• Multiple languages: English, Spanish, French, and German
• Warranty: 3-year instrument, 2-year integral cable, 1-year
polarographic sensors, 6-month galvanic sensor
Pro20i System Specifications (Instrument, Probe, and Cable) | ||
Temperature °C, °F | Range | 23 to 131°F (-5 to 55°C) 0 to 45°C for DO compensation for mg/L |
Resolution | 0.1°F (0.1°C) | |
Accuracy | ±0.6°F (±0.3°C) | |
Dissolved Oxygen % Saturation % Local | Range | 0 to 500% |
Resolution | 0.1% or 1% air saturation (user selectable) | |
Accuracy | 0 to 200% air saturation, ±2% of the reading or ±2% air saturation, whichever is greater; 200 to 500% air saturation, ±6% of the reading | |
Dissolved Oxygen mg/L ppm | Range | 0 to 50 mg/L |
Resolution | 0.01 or 0.1 mg/L (user selectable) | |
Accuracy | 0 to 20 mg/L, ±2% of the reading or ±0.2 mg/L, whichever is greater; 20 to 50 mg/L, ±6% of the reading | |
Barometer mmHg, mbar, inHg psi, kPa | Range | 400 to 999.9 mmHg |
Resolution | 0.1 mmHg | |
Accuracy | ±5 mmHg within ±5°C temperature range from calibration point |
Product Details:
Brand | Hanna |
Model | HI 98193 |
Weight | 400 g (14.2 oz.) |
Temperature | 20.0 to 120.0 degreeC (-4.0 to 248.0 degreeF) |
Battery Life | 1.5V AA batteries (4) / approximately 200 hours of continuous use without backlight (50 hours with b |
For the measurement of DO, the HI98193 is supplied with the HI764073 polarographic dissolved oxygen probe. This probe uses preformed PTFE membrane caps that are field replaceable. The probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove.
The HI98193 portable DO meter has extended ranges of up to 50 ppm and 600% saturation. When measuring dissolved oxygen, compensations for pressure, temperature, and salinity are essential for an accurate reading.
Pressure compensation can be done automatically with the meter’s built-in barometer or by manual entry. Calibration of the built-in barometer is done to one point by entering the value of a reference barometer. Pressure is displayed in user-selectable units including mmHg, inHg, atm, psi, kPa.
The HI98193 DO probe has a built-in temperature sensor for automatic temperature compensation. The temperature sensor can be calibrated to one or two points. Manual entry of salinity values allows for the salinity compensation of dissolved oxygen readings in saline waters.
Other features include built-in methods and calculations for the measurement of Biological Oxygen Demand (BOD), Oxygen Uptake Rate (OUR) and Specific Oxygen Uptake Rate (SOUR).
The HI98193’s log on-demand feature allows users to store up to 400 readings. This data can then be transferred to a PC with the HI920015 USB cable and HI92000 software.
GLP data is accessible by a fixed dedicated key this data includes date, time, pressure, calibrated value, temperature and salinity value of the last calibration.
Access help at any time at the press of a dedicated button and view content specific information based on the screen that is currently being viewed.
The high contrast graphic LCD is easy to read outdoors in bright sunlight to low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.
The compact, durable HI760193 carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter and electrode, beakers, buffer solutions, cleaning solutions and storage solutions.