A.A. Biotech Private Limited
A.A. Biotech Private Limited
Ashok Nagar, Chennai, Tamil Nadu
GST No. 33AAECA9907H1ZP
TrustSEAL Verified
Call 0804897030886% Response Rate
SEND EMAIL

Colorimeter

Manufacturer of a wide range of products which include color of water handheld colorimeter, nitrite ulr checker handheld colorimeter, checker handheld colorimeter iodine, phosphorus ulr colorimeter, iron handheld colorimeter hi 721 and color of water handheld colorimeter hi727.

Color of Water Handheld Colorimeter

Color of Water Handheld Colorimeter
  • Color of Water Handheld Colorimeter
Get Best Quote
Approx. Price: Rs 4,000 / PieceGet Latest Price
Product Brochure

Product Details:

MobilityHandheld
BrandHanna
Model No / Item CodeHI-727
ColorWhite
Resolution5 PCU
MaterialPlastic
Dimensions81.5 x 61 x 37.5 mm
Usage/ ApplicationLaboratory
Weight64 g
Light DetectorSilicon Photocell
Range0 to 500 PCU
RH Max95% non-condensing
Battery Type1.5 V AAA

Tips for an accurate measurement
  • It is important that the sample does not contain any debris.
  • Whenever the cuvette is placed into the measurement cell, it must be dry outside, and completely free of fingerprints, oil and dirt. Wipe it thoroughly with HI 731318 or a lint-free cloth prior to insertion.
  • Shaking the cuvette can generate bubbles, causing higher readings. To obtain accurate measurements, remove bubbles by swirling or by gently tapping the cuvette.
  • Do not let the reacted sample stand for too long after reagent is added, as accuracy will be affected.
  • After the reading it is important to immediately discard the sample, otherwise the glass might become permanently stained.
Request
Callback
Yes! I am interested

Nitrite ULR Checker Handheld Colorimeter

Nitrite ULR Checker Handheld Colorimeter
  • Nitrite ULR Checker Handheld Colorimeter
Get Best Quote
Approx. Price: Rs 4,000 / PieceGet Latest Price
Product Brochure

Product Details:

MobilityHandheld
BrandHanna
Model No / Item CodeHI-764
Resolution1 ppb
ColorGreen
MaterialPlastic
Dimensions81.5 x 61 x 37.5 mm
Usage/ ApplicationLaboratory
Weight64 g
Auto OffAfter 3 minutes of non-use
Range0 to 200 ppb
Battery Type1.5 V AAA

Tips for an Accurate Measurement
  • Ensure the sample does not contain any debris.
  • Whenever the cuvette is placed into the checker, it must be dry outside and free of fingerprints, oil and dirt.
  • Wipe the cuvette thoroughly with HI731318 microfiber cleaning cloth or a lint-free cloth prior to insertion.
  • Shaking the cuvette can generate bubbles, causing higher readings. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the cuvette.
  • Do not let the reacted sample stand too long after reagent has been added, as accuracy will be affected.
  • Discard the sample immediately after the reading has been taken or the glass might become permanently stained.

Request
Callback
Yes! I am interested

Checker Handheld Colorimeter Iodine

Checker Handheld Colorimeter Iodine
  • Checker Handheld Colorimeter Iodine
Get Best Quote
Approx. Price: Rs 4,200 / PieceGet Latest Price
Product Brochure

Product Details:

MobilityHandheld
BrandHanna
Model No / Item CodeHI-718
Resolution0.1 ppm
ColorBlue
MaterialPlastic
Dimensions81.5 x 61 x 37.5 mm
Usage/ ApplicationLaboratory
Weight64 g
Light DetectorSilicon Photocell
Light SourceLED @ 525 nm
Range00.0 to 12.5 ppm
Battery Type1.5 V AAA
MethodDPD method

Features:
  • Easier to use and more accurate than chemical test kits
  • DPD method±0.1 ppm ±5% of reading accuracy
  • Large, easy to read digits Auto shut off
  • Dedicated to a single parameter
  • Designed to work with Hanna’s power reagents
  • Uses 10 mL glass cuvettes small size, big convenience
  • Checker HC easily fits into the palm ofyour hand or pocketUse for quick and accurate on the spotanalysis
  • Single button operation: zero and measure Operated by a single AAA battery
  • Ideal for:Swimming pools and spas, industrial processes and disinfection
Request
Callback
Yes! I am interested

Phosphorus ULR Colorimeter

Phosphorus ULR Colorimeter
  • Phosphorus ULR Colorimeter
Get Best Quote
Approx. Price: Rs 4,000 / PieceGet Latest Price
Product Brochure

Product Details:

BrandHanna
Model No / Item CodeHI-736
Weight64 g
ColorGreen
Resolution1 ppb
MaterialPlastic
Usage/ ApplicationLaboratory
Range0 to 200 ppb
Battery Type1.5 V AAA
Dimensions81.5 x 61 x 37.5 mm

Tips for an accurate measurement
  • It is important that the sample does not contain any debris.
  • Whenever the cuvette is placed into the measurement cell, it must be dry outside, and completely free of fingerprints, oil and dirt. Wipe it thoroughly with HI 731318 or a lint-free cloth prior to insertion.
  • Shaking the cuvette can generate bubbles, causing higher readings. To obtain accurate measurements, remove bubbles by swirling or by gently tapping the cuvette.
  • Do not let the reacted sample stand for too long after reagent is added, as accuracy will be affected.
  • After the reading it is important to immediately discard the sample, otherwise the glass might become permanently stained.
Request
Callback
Yes! I am interested

Iron Handheld Colorimeter HI 721

Iron Handheld Colorimeter HI 721
  • Iron Handheld Colorimeter HI 721
Ask For Price
Product Price :Get Latest Price

Product Details:

Model No / Item CodeHI721
Resolution0.01 A
DetectorSilicon Photodiode

Light High: There is too much light to perform a measurement. Please check the preparation of the zero cuvette. Light Low: There is not enough light to perform a measurement. Please check the preparation of the zero cuvette. Inverted Cuvettes: The sample and the zero cuvette are inverted. Under Range: A blinking “0.00” indicates that the sample absorbs less light than the zero reference. Check the procedure and make sure you use the same cuvette for reference (zero) and measurement. Over Range: A flashing value of the maximum concentration indicates the reading is over range. Dilute the sample and re-run the test. Battery Low: The battery must be replaced soon. Dead Battery: This indicates that the battery is dead and must be replaced. Once this indication is displayed, normal operation of the instrument will be interrupted. Change the battery and restart the mete
Request
Callback
Yes! I am interested

Color of Water Handheld Colorimeter HI727

Color of Water Handheld Colorimeter HI727
  • Color of Water Handheld Colorimeter HI727
Ask For Price
Product Price :Get Latest Price

Product Details:

Resolution0.01 A
Accuracy0.5 % FSI
DetectorSilicon Photodiode

Light High: There is too much light to perform a measurement. Please check the preparation of the zero cuvette. Light Low: There is not enough light to perform a measurement. Please check the preparation of the zero cuvette. Inverted Cuvettes: The sample and the zero cuvette are inverted. Under Range: A blinking “0” indicates that the sample absorbs less light than the zero reference. Check the procedure and make sure you use the same cuvette for reference (zero) and measurement. Over Range: A flashing value of the maximum concentration indicates the reading is over range. Dilute the sample and re-run the test. Battery Low: The battery must be replaced soon. Dead Battery: This indicates that the battery is dead and must be replaced. Once this indication is displayed, normal operation of the instrument will be interrupted. Change the battery and restart the meter.
Request
Callback
Yes! I am interested

Checker Handheld Colorimeter Iodine HI 718

Checker Handheld Colorimeter Iodine HI 718
  • Checker Handheld Colorimeter Iodine HI 718
Ask For Price
Product Price :Get Latest Price
HI 718 Checker®HC is supplied with (2) sample cuvettes with caps, (6) powder reagents for iodine, (1) 1.5V AAA battery and instructions
Request
Callback
Yes! I am interested

Nitrite ULR Checker Handheld Colorimeter HI764

Nitrite ULR Checker Handheld Colorimeter HI764
  • Nitrite ULR Checker Handheld Colorimeter HI764
Ask For Price
Product Price :Get Latest Price

Product Details:

DetectorSilicon Photodiode

HI764 Checker®HC is warranted for a period of one year against defects in workmanship and materials when used for its intended purpose and maintained according to instructions. This warranty is limited to repair or replacement free of charge. Damage due to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service is required, contact your local Hanna Instruments Office. If under warranty, report the model number, date of purchase, serial number and the nature of the problem. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the checker is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization (RGA) number from the Technical Service department and then send it with shipping costs prepaid. When shipping any product, make sure it is properly packaged for complete protection. Hanna Instruments reserves the right to modify the design, construction, or appearance of its products without advance notice.
Request
Callback
Yes! I am interested

Phosphorus ULR HI 736 Colorimeter

Phosphorus ULR  HI 736 Colorimeter
  • Phosphorus ULR  HI 736 Colorimeter
Ask For Price
Product Price :Get Latest Price
Light High: There is too much light to perform a measurement. Please check the preparation of the zero cuvette. Light Low: There is not enough light to perform a measurement. Please check the preparation of the zero cuvette. Inverted cuvettes: The sample and the zero cuvette are inverted. Under range: A blinking “0” indicates that the sample absorbs less light than the zero reference. Check the procedure and make sure you use the same cuvette for reference (zero) and measurement. Over Range: A flashing value of the maximum concentration indicates an over range condition. The concentration of the sample is beyond the programmed range: dilute the sample and re-run the test. Battery low: The battery must be replaced soon. Dead battery: This indicates that the battery is dead and must be replaced. Once this indication is displayed, normal operation of the instrument will be interrupted. Change the battery a
Request
Callback
Yes! I am interested
X

Product Videos

Watch More Videos

Explore More Products

View All Products




Reach Us
Udaya Ram Jothy (Managing Director)
A.A. Biotech Private Limited
No. 16/1, 48th Street, 9th Avenue
Ashok Nagar, Chennai - 600083, Tamil Nadu, India


Call Us


Send E-mail